Observation Possible Cause Corrective Action
Loss of "bond" to investment Retention tabs "Bond" between Densulate and gypsum is mechanical not chemical. When Densulate is partially set, use a finger or instrument to lift material to create mechanical retention.
Inadequate thickness A minimum coverage of 2 mm should be used to maintain the strength of the tabs.
Set time Allow the material to completely set before pouring upper half of the flask.
Packing pressure Excessive pressure during flask closure may cause the denture base flowing out of the flask to stretch the Densulate thereby pulling it out of the investment.
Tooth movement Open bite Remove material from the incisal and occlusal surfaces during flasking procedures to provide a solid seat for teeth.